RALE Engineering  GmbH provides you with design examples for typical small transformers, large transformers, toroidal transformers and small chokes & inductors

FOR FREE

to help you save time and money.

Check them out and benefit from RALE’s know-how.

Get a booklet with 13 design examples (assembled by Pamela and Dan – our representatives for USA and Canada).

Below you will find design examples. We have also included the input files for almost each of the examples. You will find most of them at the top of each example. Just click.

Designing inherently short-circuit-proof, potted safety transformers up to 10VA with the Rale Design Software, in accordance with IEC 61558

Design a not short-circuit-proof 18VA – low profile safety transformer as per IEC 61558, protected by a miniature fuse in accordance with IEC 127.

Design a 60VA (long stack EI42/98) – non-inherently short-circuit proof safety transformer for halogen lamps in accordance with IEC 61558, protected by a thermal fuse

Design a rectifier safety transformer for feed to voltage controllers of 5Vdc,1Adc and 2x12Vdc,0.1Adc with RC-loading accordance with IEC 61558

Design a three-phase rectifier/safety transformer for 24Vdc, 80Adc with RC load, as per IEC 38 and IEC 61558 ?

Design a low inrush current universal control transformer for 800VA continuous output power
 as per IEC 61558

Design an 8000VA transformer for medical premises in accordance with IEC 61558 

Design a 50kHz, 1200VA transformer as per IEC 61558

Design a 100kHz, universal flyback transformer for input voltage125-700Vdc and output power 200W

Design a 250kHz, 120W forward transformer with voltage controller, for input voltage range 200V to 350V, as per IEC 61558

Design a low inrush current three phase universal autotransformer for 10kVA continuous output power as per IEC 61558

Design a motor starting three-phase autotransformer for 100kVA continuous motor power as per IEC 61558

Designing non-short-circuit-proof, low profile safety transformers up to 42VA with Rale Design System, in accordance with IEC 61558,
protected by miniature fuse as per IEC 127

Design a 50kHz, 240W resonance transformer for a LLC converter.

Information for our customers: All single phase design examples (up to 10 kVA, 50/60 Hz) calculated with the Small Transformer Program can also be calculated with the Toroidal Transformer Program.

How do we design a toroidal current transformer?